Ajax TOCCO Toccotron AC Especificaciones Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
OM-229 158 Page 16
804 597-A
4-9. Remote 14 Receptacle RC14 Information and Connections
1. Plug
2. Threaded Collar
3. Keyway
4. Remote 14 Receptacle RC14
(See Section 4-10)
To connect to receptacle, align key-
way, insert plug and tighten
threaded collar.
AJ
B
K
I
C
L
NH
D
M
G
E
F
3
4
2
1
4-10. Remote 14 Socket Information
Socket Socket Information
A
B
Remote Contactor
+24 volts DC.
Contact closure to A completes 24 volts DC contactor control circuit.
C
D
E
G
Remote Output Control
Command reference; +10 volts DC.
Control circuit common.
Input command signal (potentiometer wiper or 0 to +10 volts DC).
Not used.
F, J Power Source Limit
Absence of internal contact closure between F and J signals power source error to remote
control device.
H
I
L
M
N
K
Remote Metering
Not used.
Actual frequency output signal (1 volt/10 kHz).
Average power output signal (1 volt/10 kW).
Voltage output signal RMS (1 volt/100 volts).
Total current output signal RMS (1 volt/100 amperes).
Chassis common.